...setting the standard again and again
®
46
Conductivity Accessories
Calibration Solutions and Accessories
Conductivity/
TDS Cells
Choose from three cell constants
All cells feature built-in temperature
compensation. A 1.0 cell constant (K)
is ideal for midrange conductivity
measurements. For high conductivity
measurements (near or above 20 mS)
order a cell with K = 10.0; for low
conductivity measurements (near or
below 20 μS), order a cell with K = 0.1.
Catalog
number
Body/sensor
material
Cell
constant
Temperature
range
Cable
length
Probe
style
Cells for use with CON 6, TDS 6, and SALT 6
WD-35606-53
Ultem K = 0.1 0 to 80°C 3 ft C
WD-35606-55
Ultem K = 1.0 0 to 80°C 3 ft C
WD-35606-57
Ultem K = 10 0 to 80°C 10 ft C
Cells for use with CON 400, CON 410, TDS 400, CON 510,
pH/CON 300, pH/CON 510, CON 11, and CON 110
WD-35608-50
Ultem K = 1.0 0 to 80°C 3 ft C
WD-35608-57
Ultem K = 1.0 0 to 80°C 10 ft C
WD-35608-51
Epoxy K = 10 0 to 80°C 3 ft A
WD-35608-52
Glass K = 1.0 0 to 100°C 3 ft B
WD-35608-55
Epoxy K = 0.1 0 to 80°C 3 ft A
Cells for use with CON 600, CON 610, PC 650, CD 650, and PCD 650
WD-35408-50
Epoxy K = 0.1 0 to 80°C 3 ft A
WD-35408-52
Ultem K = 1.0 0 to 80°C 3 ft C
WD-35408-57
Ultem K = 1.0 0 to 80°C 10 ft C
WD-35408-54
Epoxy K = 10 0 to 80°C 3 ft A
WD-35408-56
Epoxy, 4-cell K = 0.3 0 to 80°C 3 ft A
WD-35408-58
Epoxy K = 0.01 0 to 80°C 3 ft A
Conductivity/TDS
Calibration Solutions
NIST-traceable; ±1% accuracy at 25°C
Conductivity/TDS calibration solutions are cross
checked using different test methods, premixed,
and ready to use. Each one-pint bottle is labeled
with the name and CAS number for all ingredients
to conform with “Right-to-Know” requirements.
Catalog
number
Conductivity
value
Conductivity-to-TDS calibration values
ppm KCl ppm NaCl ppm 442
WD-00653-23
23 μS 11.6 10.7 14.74
WD-00653-16
84 μS 40.38 38.04 50.50
WD-00653-47
447 μS 225.6 215.5 300.0
WD-00653-18
1413 μS 744.7 702.1 1000
WD-00653-15
1500 μS 757.1 737.1 1050
WD-00653-27
2070 μS 1045 1041 1500
WD-00653-20
2764 μS 1382 1414.8 2062.7
WD-00653-89
8974 μS 5101 4487 7608
WD-00606-10
12,880 μS 7447 7230 11,367
WD-00653-50
15,000 μS 8759 8532 13,455
WD-00653-32
80 mS 52,168 48,384 79,688
Conductivity/TDS “Singles”
Calibration Pouches
NIST traceable for high accuracy;
±1% accuracy at 25°C
Conductivity/TDS “Singles” are
convenient, individually sealed
pouches that contain high-precision
calibration standards. Ideal for field
calibration; just select the pouches
you need and carry them to your
test site for on-the-spot calibration
and verification. Pouches are labeled
with equivalent values for KCl, NaCl,
and 442 and conductivity values at
25°C and CAS numbers for “Right-
to-Know” requirements. Each box
contains twenty 20-mL pouches.
Catalog
number
Conductivity
value
Conductivity-to-TDS calibration values
ppm KCl ppm NaCl ppm 442
WD-35653-09
10 μS 4.7 4.8 7.0
WD-35653-10
447 μS 225.6 215.5 300.0
WD-35653-11
1413 μS 744.7 702.1 1000
WD-35653-12
2764 μS 1382 1414.8 2062.7
WD-35653-13
15,000 μS 8759 8532 13,455
WD-35653-15
5,650 μS 3240 3000
WD-35653-00 “Singles” deionized rinse water pouches, 20 pouches/box
Portable Printer
Use with the CON 110 portable meter (pg 42)
Create permanent records
of your data from Oakton®
meters with RS-232 output!
This printer’s compact size
and rechargeable battery
pack make it the perfect
printer for both field use
and crowded benchtop
space. Pre-configured setup
selections match the exact
parameters of your meter.
Accepts standard-sized
adding machine rolls and
printer ribbons.
Catalog number Description Power
WD-35622-00
Portable printer 110 VAC
WD-35622-05
Portable printer 220 VAC
WD-35622-59 Printer cable, connects printer to your CON 110 meter
(or other meters with RS-232 output)
WD-35622-60 Replacement ribbon cartridge
WD-35622-62 Replacement paper, one roll