...setting the standard again and again
®
2
pH/ORP Introduction / Testers
pH Measurement
Waterproof pHTestrs
®
and ORPTestrs
®
Selection Guide
Use this chart to find the best Testr for your application
Meter pHTestr Basic pHTestrs 10, 20, 30 pHTestr 10 BNC pH Spear ORPTestr 10 ORPTestr 10 BNC
Page
547688
Parameters
pH pH and temperature pH pH ORP ORP
Electrode
Single-junction
module
Double-junction
module
Not included—use any
electrode with BNC
connector
Double-junction
spear-tip probe
Double-junction ORP
module
Not included—use any
electrode with BNC
connector
Resolution
Up to 0.01 0.1 Up to 0.01 Up to 0.01 1 mV 1 mV
Accuracy
Up to ±0.01 ±0.1 Up to ±0.01 Up to ±0.01 ±2 mV ±2 mV
Display
One-line LCD T
wo-line LCD Two-line LCD Two-line LCD Two-line LCD Two-line LCD
Calibration
3 points;
US buffers
3 points;
US or NIST buffers
3 points;
US or NIST buffers
3 points;
US or NIST buffers
±150 mV offset
±150 mV offset
What is pH Measurement? The most commonly measured
chemical parameter in aqueous solutions, pH is a measure
of a liquid’s acidity and alkalinity. It is a critical parameter
in water and wastewater treatment in
municipal and industrial applications,
chemical production, agriculture
research, and production. It is also
critical in environmental monitoring,
chemical and life sciences research,
biochemical and pharmaceutical
research, electronics production, and
many more applications.
Meter Selection. Oakton offers a
large selection of pH measurement
instruments and kits. From pocket-sized
pHTestrs
®
, to rugged handheld meters,
to laboratory benchtop meters, Oakton
has an instrument for practically any
pH application.
Electrode Selection. Proper pH electrode
selection is important to maximize electrode life and ensure the
best possible accuracy for your application. Oakton offers a
complete selection guide with
applications and specifications for pH
range, temperature, and diameter for
each electrode (see pages 28–33).
Calibration Buffers. All pH
measurement requires calibration
solutions to ensure that the readings
are traceable to a standard. Oakton
calibration buffers do this—and
more—since they are standardized
against NIST-certified references.
Always choose a pH 7 buffer plus
at least one other pH value close to
your expected measurement range.
Storage and cleaning solutions
should also be used to ensure fast,
reliable results from your electrodes.
Expert Advice to Ensure the Best Results. Feel free to contact
an Oakton distributor to help you choose your Oakton pH
measurement products. Oakton distributors are dedicated to
helping you purchase the Oakton instrument that will give you
the best results.