...setting the standard again and again
®
26
pH/ORP Electrodes
Electrodes for Laboratory and Field
Applications
All Oakton
®
electrodes have a BNC-connected combination
reference cell and measuring cell in one housing for easy use
Oakton offers a variety of electrodes for your general-purpose and specialty laboratory applications. The
“Application Guide” below provides information to help you find the electrode that best fits your application.
Carefully choose the electrode best suited for your application to ensure accurate pH measurements. The guide
only offers suggestions—contact your Oakton Technical Product Specialist for more specific recommendations
or clarification. Shipping dimensions for all electrodes are 9.25" x 1.75" x 2.75". Shipping weight 0.5 lb each.
Use and Care of Electrodes
HandlingElectrodes should be rinsed between samples with
distilled or deionized water. Never wipe an electrode—wiping can
cause erroneous readings due to static charges. Gently blot the end of
the electrode with lint-free paper to remove excess water.
Refillable Electrodes—see page 32 for reference solutions.
The filling solution in refillable electrodes should be filled up to, but
not past, the refill hole. Make sure the refill hole is left open when
measuring to ensure that the fill solution flows properly through the
reference junction.
Storage—see page 29 for storage products.
Always keep your pH electrode moist. We recommend that you store
your electrode in an electrode storage solution of 4 M KCl (see page
29). If 4 M KCl is not available, use a pH 4 or 7 buffer solution. DO NOT
store electrode in distilled or deionized water—this will cause ions to
leach out of the glass bulb and reference electrolyte, rendering your
electrode useless.
Electrode Types
Built-in temp
sensor
Use electrode with the following meters
Standard: Most economical electrode; includes cable.
No
pHTestr BNC,
pH 5/6, Ion 6, pH 10/11/100/110, pH 300/310,
pH 500/510, Ion 510, pH 1000/1100/2100/2500, pH/DO 300,
pH/CON 300, pH/CON 510, pH 600/610/620, PC600, PD600,
PDC650, and non-Oakton meters with BNC pH electrodes
All-in-One: Combination pH electrode/temperature sensor; includes cable.
Ye
s
Standard:
pH 10/100, pH 500, pH 1000/2500
Acorn
®
: pH 5/6, Ion 6, pH 11/110, pH 510, Ion 510, pH 1100/2100
Waterproof: pH 300/310, pH/CON 300, pH/CON 510
WP600: pH 600/610/620, PC600, PD600, PCD650
Direct connect: Electrode connects directly to meter; no cable.
No
pHT
estr BNC
ORP: Takes mV readings; includes cable.
No
Ion 5/6,
pH 6,
pH 10/100, pH 300/310, pH 500,
pH 510, Ion 510, pH 1000/2100/2500, pH/CON 510
ISE: Takes ion-selective readings; includes cable. See pages 40-41 for ISEs
No
Ion 5/6, pH 10/100,
pH 300/310, pH 500, pH/CON 510;
pH 510, Ion 510, pH 1000/1100/2100/2500
Application Guide
Application Suggested electrode
Drinking water
Standard Ag/AgCl with single junction
Wastewater, solutions with
heavy metals
Double junction solutions
Biological samples, proteins, and
Tris buffers
Calomel or double junction
Pharmaceuticals
Low ionic strength samples
Flushable or sleeve-type refillable electrode
Boiler feed water and distilled water
Soil samples
Soil electrode, double junction
Moist flat surfaces, concrete, cheese,
agar, paper
, and skin
Flat-surface, calomel
Semisolid samples, food, fruits,
cheese, and meat
Spear tip
Nonaqueous samples, solvents,
alcohols, viscous samples, slurries,
suspended solids, sludges, emulsions
and oils, paints, and inks
Sleeve-type, flushable, or double junction
electrode and fill with electrolyte containing
methanol
Environmental, surface water,
neutralization tanks
Double junction submersible
Temperature Probes
Order a temperature probe if you have an electrode without
a built-in temperature sensor and you want to take readings
with Automatic Temperature Compensation (ATC). Separate
temperature probes offer faster temperature response and
lower pH electrode replacement cost.
Catalog number Use with
WD-35615-05
pH 10, pH 100, pH 500, pH 1000, and pH 2500 meters
WD-35613-05
pH 5,
pH 6,
and Ion 6 Acorn
®
meters; pH 11, pH 110, pH 510,
Ion 510, pH 1100, and pH 2100 benchtop meters
WD-35618-05
pH 300,
pH 310,
and pH/CON 300 waterproof meters;
pH/CON 510 benchtop meter
WD-35418-05
pH 600/610/620,
PC600,
PD600, PCD650 meters
Oakton electrodes are shipped with a protective electrode
storage bottle to help prevent cracking or scratching, and to
keep the bulb moist. Remove the electrode storage bottle before
using your electrode. Keep your electrode in the bottle for
long-term storage—just fill the bottle with enough 4 M KCl
solution to cover the glass bulb and replenish as needed.
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682