...setting the standard again and again
®
pH/ORP Benchtop Meters
Simple to use
Preprogrammed calibration points
make meter easy to use
Direct readout of ion
concentration in ppm
Resolution to 0.01 ppm
Dual display
Shows measured parameter and °C
in pH/mV modes; ion concentration
and mV (electrode output)
in ion mode
Features 0.1 mV resolution for
ORP measurements
Simultaneous display of ppm and mV
electrode output in the ion mode
Verify electrode operation while
taking measurements
Selectable buffer sets and
three-point pH calibration
with auto buffer recognition
Choose from USA or NIST
buffer sets
Works with many
ion-selective electrodes
±1999 mV range covers most ISEs
Built-in electrode stand
Holds electrode firmly in place
Selectable manual or automatic
temperature compensation
For highest accuracy in any situation
Built-in memory function
Stores up to 50 ion, mV, or
pH readings
Analog recorder output
Create hard copies of your readings
Hold function, “Ready” indicator,
diagnostic messages
Slide-out instruction card for
quick reference
The Ion 510 meter includes
built-in electrode stand
and handy slide-out
instruction card.
Ion 510 Meter
A benchmark in economical pH, mV,
and direct ion concentration measurement
without sacrificing quality and performance!
Input impedance: >10
12
:
Temperature compensation: selectable manual or
automatic from 0 to 100°C
Memory: up to 50 sets
Recorder output: ±2000 mV (directly proportional to input)
Recorder output connector: mini pin (subminiature
phono plug)
Display: dual display of pH or mV with temperature or
ppm with mV electrode output mode annunciators
Error messages: diagnose operator error, electrode error,
and meter error. Pull-out instruction card decodes
message
Operating temperature: 0 to 50°C,
noncondensing humidity
Power: 9 VDC, 500 mA; using AC adapters (included);
110 VAC, 60 Hz or 220 VAC, 50 Hz. AC adapter is
UL and CSA listed.
Dimensions
Meter: 9"W x 7"D x 2.375"H (23 x 18 x 6 cm)
Boxed: 15.5"W x 10"D x 3.5"H (39 x 25 x 9 cm)
Weight
Meter only: 1.25 lb (0.6 kg); Boxed: 3 lb (1.4 kg)
Ordering Information
Catalog number Description Included
WD-35619-22
Ion 510 meter only Meter, built-in electrode stand, and AC adapters
WD-35619-20
Ion 510 meter
Meter, double-junction pH electrode 35805-04, temperature probe 35613-05,
built-in electrode stand, and AC adapters
WD-35619-23
Ion 510 meter
Meter
, “All-in-One” combination temperature sensor/single-junction
pH electrode 35811-71, built-in electrode stand, and AC adapters
35619-20
Specifications
Mode Ion mV pH Temperature
Range
0.01 to 1999 ppm ±1999 mV 0.00 to 14.00 pH 0.0 to 100.0 °C
Resolution
0.01 ppm from 0.01 to 0.99 ppm,
0.1 ppm from 1.0 to 199.9 ppm,
1 ppm from 200 to 1999 ppm
0.1 mV from ±199.9 mV
,
1 mV beyond ±199.9 mV
0.01 pH
0.1 °C
Accuracy
±0.5% of reading
±0.2 mV from ±199.9 mV
,
±2 mV beyond ±199.9 mV
±0.01 pH
±0.3 °C
Calibration
2 or 3 points, 0.1; 1; 10;
100 ppm (minimum 2 points)
Offset up to ±150 mV
Up to 3 points
(USA: 4.01; 7.00; 10.01
or NIST
: 4.01, 6.86; 9.18);
auto-buffer recognition
Offset 0.1°C
increments
meter only
Ion-selective and pH
electrodes are available
on pages 25–30.
20
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682