Order Code: Specifications:
Conductivity Cells
EC91346S
Conductivity range
Up to 500 mS/cm
Cell constant, k 0.3, 4-Cell
Temperature sensor Pt 100, 3-wire
Pressure rating 6 bar
Material Ryton, SS 316
Thread
3
/
4
” NPT
Cable Integrated 7.6m, 8-wire double-shielded, open
Dimension: Length (excludes cable) 150.5 mm
Diameter (external) 22.2 mm
Weight 650 g
ECCS10-0-01T
Conductivity range
Up to 20 µS/cm
Cell constant, k 0.01, 2-Cell
Temperature sensor Pt 100, 3-wire
Pressure rating 6 bar
Material Titanium
Thread ½” NPT
Cable Integrated 7.5m, 6-wire double-shielded, open
Dimension: Length (excludes cable) 168 mm
Diameter (external) 12.8 mm
Weight 595 g
ECCS10-0-01S
Conductivity range Up to 20 µS/cm
Cell constant, k 0.01, 2-Cell
Temperature sensor Pt 100, 3-wire
Pressure rating 6 bar
Material SS 316
Thread ½” NPT
Cable Integrated 7.5m, 6-wire double-shielded, open
Dimension: Length (excludes cable) 168 mm
Diameter (external) 12.8 mm
Weight 595 g
ECCS10-0-1S
Conductivity range 0.1 to 200 µS/cm
Cell constant, k 0.1
, 2-Cell
Temperature sensor Pt 100, 3-wire
Pressure rating 6 bar
Material SS 316
Thread ½” NPT
Cable Integrated 7.5m, 6-wire double-shielded, open
Dimension: Length (excludes cable) 168 mm
Diameter (external) 12.8 mm
Weight 595 g
ECCS10-1-0S
Conductivity range Up to 100 mS/cm
Cell constant, k 1.0
, 2-Cell
Temperature sensor Pt 100, 3-wire
Pressure rating 6 bar
Material SS 316
Thread ½” NPT
Cable Integrated 7.5m 6-wire double-shielded, open
Dimension: Length (excludes cable) 168 mm
Diameter (external) 12.8 mm
Weight 595 g
Order Code: Specifications:
Dissolved Oxygen Probes
ECDOGEN
Dissolved oxygen range 0.5 to 40 ppm
Type Galvanic
Flow rate 1 to 2 cm/s (dependent on temperature and O
2
level)
Response time 40 to 50 secs to attain 95% of actual reading
Temperature sensor Pt 100
Pressure rating 6 bar
Material Delrin housing
Membrane Teflon
Cable Integral 5m water-resistant, open
Dimension: Length (excludes cable) 69.5 mm
Diameter (external) 58.0 mm
Weight 670 g
ECDOTPII
Dissolved oxygen range 0 to 10 ppm
Type Galvanic
Flow rate 1 to 2 cm/s (dependent on temperature and O
2
level)
Response time 40 to 50 secs to attain 95% of actual reading
Temperature sensor Pt 100
Pressure rating 6 bar
Material Delrin housing
Membrane Teflon
Cable Integral 5m water-resistant, open
Dimension: Length (excludes cable) 69.5 mm
Diameter (external) 58.0 mm
Weight 670 g
12
Przeglądanie stron 2
1 2 3 4 5 6 7 8 ... 12 13

Komentarze do niniejszej Instrukcji

Brak uwag